FEDERAL TRADE COMMISSION

16 CFR Part 460

TRADE REGULATION RULE:
LABELING AND ADVERTISING OF HOME INSULATION

AGENCY: Federal Trade Commission.

ACTION: Advance notice of proposed rulemaking.

SUMMARY: The Federal Trade Commission ("Commission") proposes commencing a rulemaking proceeding to amend its Trade Regulation Rule Concerning the Labeling and Advertising of Home Insulation ("R-value Rule" or "Rule"). The purpose of the rulemaking is to streamline and increase the benefits of the Rule to consumers and sellers, minimize its costs, and respond to the development and utilization of new technologies to make American homes more energy efficient and less costly to operate. This notice: (1) summarizes public comments the Commission received in response to a request for comments about the need for the Rule and its benefits and burdens; (2) proposes amendments to recognize technological advances in R-value testing and specimen preparation procedures, and to clarify and streamline the Rule's requirements; and (3) solicits comments on the proposed amendments and additional issues.

DATE: Written comments must be submitted on or before November 15, 1999.

ADDRESS: Five paper copies of each written comment should be submitted to the Office of the Secretary, Federal Trade Commission, Room 159, 600 Pennsylvania Ave., N.W., Washington, D.C. 20580. All comments also should be submitted, if possible, in electronic form, on a 3-1/2 inch personal computer diskette, with a label on the diskette stating the name of the commenter and the name and version of the word processing program used to create the document. Programs based on DOS are preferred. Files from other operating systems should be submitted in ASCII text format. Individuals filing comments need not submit multiple copies or comments in electronic form. Comments alternatively may be submitted by electronic mail (e-mail) to <rvalue@ftc.gov . Submissions should be identified as "ANPR Comment, R-value Rule, 16 CFR Part 460."

FOR FURTHER INFORMATION CONTACT: Kent C. Howerton or James G. Mills, Attorneys, Federal Trade Commission, Washington, DC 20580, (202) 326-3013 or (202) 326-3035 (voice), or (202) 326-3259 (FAX).

SUPPLEMENTARY INFORMATION:

I. INTRODUCTION

According to the U.S. Department of Energy ("DOE"), the typical U.S. family spends close to $1,300 each year on energy bills. DOE statistics show that, typically, 44% of a homeowner's utility bill goes for heating and cooling costs. DOE states that homeowners may be able to reduce their energy bills from 10% to 50% by taking certain steps.(1) One of the major steps is increasing the amount of thermal insulation in their existing homes, or purchasing additional insulation when purchasing new homes.

To assist consumers in reducing energy bills, the President of the United States announced in 1998 the Partnership for Advancing Technology in Housing ("PATH"). PATH is a public/private sector initiative that seeks to expand the development and utilization of new technologies in order to make American homes stronger, safer and more durable; more energy efficient and environmentally friendly; easier to maintain and less costly to operate; and more comfortable and exciting to live in. The PATH effort is expected to result in, among other things, improved energy efficiency and the increased market acceptance of new housing technologies.

The FTC has long recognized the importance of energy expenditures on housing to homeowners and other consumers. In 1979, the Commission promulgated the R-value Rule, 16 CFR Part 460. The R-value Rule requires that thermal insulation manufacturers and other sellers disclose the thermal performance of their products, based on uniform testing procedures adopted by the thermal insulation industry. The purpose of this Rule is to provide consumers with information about thermal insulation products, based on uniform standards, that allows them to make meaningful, cost-based purchasing decisions among competing products. As part of its ongoing program to review all its rules and guides to ensure that they provide the maximum benefits at the lowest cost, the Commission reviewed the R-value Rule in 1995 and adopted amendments in 1996 to support the use of the most current testing procedures available and to streamline the Rule.

To increase further the benefits of the Rule, reduce its costs, and support PATH's goals to make American homes more energy efficient, and less costly to operate, the Commission now proposes to consider amending the Rule to recognize the latest technology available. At this time the Commission proposes only a few limited amendments, which are designed to clarify the Rule, make disclosure requirements consistent for competing types of loose-fill insulation products, require the most current procedures for preparing R-value test specimens and conducting R-value tests, delete disclosures for a type of insulation that no longer is sold, and reduce disclosure requirements for retailers. Regarding these issues, the Commission believes that there is sufficient information to propose amendments. Regarding other issues, the Commission is not proposing amendments at this time, but seeks additional comment that could ultimately result in proposed amendments. The Commission, therefore, requests comments on additional issues, such as whether the Commission should revise the Rule to cover additional products or to require the disclosure of in-use performance values (as opposed to laboratory tests that are conducted under static, uniform conditions) or of the performance of building systems. In addition, the Commission requests comments on whether it should adopt additional test specimen preparation requirements for specific types and forms of insulation products to account for various factors that affect R-values; adopt additional or updated testing requirements; and revise the disclosure requirements for manufacturers' labels and fact sheets, advertisements and other promotional materials, and for professional installers, new home sellers, and retailers.

II. THE R-VALUE RULE

The Commission promulgated the R-value Rule on August 29, 1979(2) under section 18 of the Federal Trade Commission Act ("FTC Act"), 15 U.S.C. 57a. The Rule became effective on September 30, 1980. The Rule specifies substantiation and disclosure requirements for those who sell thermal insulation products for use in the residential market, and prohibits certain claims unless they are true. The primary disclosure required is the insulation product's "R-value." "R-value" is the recognized numerical measure of the ability of an insulation product to restrict the flow of heat and, therefore, to reduce energy costs. R-values may be expressed per unit of thickness (e.g., one inch) or for the total thickness of a particular insulation product or installation. The higher the R-value, the better the product's insulating ability.

On April 6, 1995, as part of its ongoing regulatory review program, the Commission solicited public comments about the economic impact of and current need for the R-value Rule.(3) 60 FR 17492 (1995). At the same time, the Commission solicited comments on a petition ("Petition") from Ronald S. Graves, who at that time was a Research Staff Member, Materials Analysis Group, Martin Marietta Energy Systems, Inc. (which operates Oak Ridge National Laboratory ("ORNL") for the U.S. Department of Energy ("DOE")). The Petition requested that the Commission approve an additional (fifth) R-value test procedure, as an optional test procedure for determining the R-value of home insulation under the Rule. The test procedure had been issued by the American Society for Testing and Materials ("ASTM"), a voluntary industry standards organization.

In response to the request for comments, the Commission received 42 comments from manufacturers of cellular plastics, cellulosic, mineral fiber, and reflective insulation products; manufacturers of structural insulated panels; trade associations comprised of manufacturers of insulation products and structural insulated panels, professional installers, and roofing contractors; independent technical consultants to industry; a government contractor; and individual consumers.(4)

Thirty of the 31 comments that addressed the current need for the Rule stated that there is a continuing need for the Rule (and its requirements that manufacturers and other sellers substantiate and disclose the R-values of home insulation products). Twenty-four comments described benefits that the current Rule, and the disclosure of R-values and related information, confer on consumers and home insulation sellers, including: (1) giving consumers the basic thermal performance information (i.e., R-values) they need to select products with the R-value they want; (2) giving consumers R-value information in a uniform manner that facilitates easy comparison of competing products; (3) requiring that R-value claims be substantiated so consumers receive what they are promised; (4) helping consumers save energy (and heating and cooling costs) by preventing misrepresentations about R-values of insulation products; (5) saving consumers money by eliminating marketing practices that lead them to over- or underinsulate; (6) improving the quality and consistency of home insulation and encouraging the development of advanced products; and (7) creating a "level playing field" for competing insulation sellers.(5) Most of the comments stated that the costs the Rule imposes on consumers and sellers are minimal.

Based on the comments, the Commission determined that there is a continuing need for the Rule, published its determination to retain it, and adopted several technical, non-substantive amendments to support the use of the most current testing procedures available and to streamline the Rule.(6) 61 FR 13659, at 13659-62, 13665 (1996). The comments also discussed other issues and recommended that the Commission consider additional Rule amendments. These comments, the Commission's discussion of the issues the comments raised, proposed revisions to the Rule, and objectives and regulatory alternatives to the proposed revisions, are summarized in Part IV.

III. OVERVIEW OF THE RULE(7)

A. Products Covered

The R-value Rule covers all "home insulation products." Under the Rule, "insulation" is any product mainly used to slow down the flow of heat from a warmer area to a cooler area, for example, from the heated interior of a house to the exterior during the winter through exterior walls, attic, floors over crawl spaces, or basement. "Home insulation" includes insulation used in all types of residential structures. The Rule automatically covers new types or forms of insulation marketed for use in the residential market, whether or not they are specifically referred to in the Rule. The Rule does not cover pipe insulation, or any type of duct insulation except for duct wrap. The Rule does not cover insulation products sold for use in commercial (including industrial) buildings. It does not apply to other products with insulating characteristics, such as storm windows or storm doors.

Home insulation includes two basic categories: "mass" insulations and "reflective" insulations. Mass insulations reduce heat transfer by conduction (through the insulation's mass), convection (by air movement within and through the air spaces inside the insulation's mass), and radiation. Reflective insulations (primarily aluminum foil) reduce heat transfer not through the mass of the product, but, when installed facing an airspace, by increasing the thermal resistance of the airspace by reducing heat transfer by radiation through it. 44 FR at 50219. Within these basic categories, home insulation is sold in various types ("type" refers to the material from which the insulation is made, e.g., fiberglass, cellulose, polyurethane, aluminum foil) and forms ("form" refers to the physical form of the product, e.g., batt, dry-applied loose-fill, spray-applied, boardstock, multi-sheet reflective).

B. Parties Covered

The Rule applies to home insulation manufacturers, professional installers, retailers who sell insulation to consumers for do-it-yourself installation, and new home sellers (including sellers of manufactured housing). It also applies to testing laboratories that conduct R-value tests for home insulation manufacturers or other sellers who use the test results as the basis for making R-value claims about home insulation products.

C. Purpose of the Rule

The main reason consumers purchase home insulation is to reduce energy expenditures to heat and cool their homes. To assist consumers, the Rule requires sellers (including insulation manufacturers, professional installers, new home sellers, and retailers) to disclose the insulation product's R-value and related information, prior to retail sale, based on uniform, industry-adopted standards. This information enables consumers to evaluate how well a particular insulation product is likely to perform, to determine whether the cost of the insulation is justified, and to make meaningful, cost-based purchasing decisions among competing products.

D. Basis for the Rule

The Commission issued the R-value Rule to prohibit, on an industry-wide basis, specific unfair or deceptive acts or practices. When it issued the Rule, the Commission found that the following acts or practices were prevalent in the home insulation industry and were deceptive or unfair, in violation of section 5 of the FTC Act, 15 U.S.C. 45: (1) sellers had failed to disclose R-value, and caused substantial consumer injury by impeding the ability of consumers to make informed purchasing decisions, 44 FR at 50222-23; (2) the failure to disclose R-values, which vary significantly among competing home insulation products of the same thickness and price, misled consumers when they bought insulation on the basis of price or thickness alone, Id. at 50223; (3) sellers had exaggerated R-values, often failing to take into account factors (e.g., aging, settling) known to reduce thermal performance, Id. at 50223-24; (4) sellers had failed to inform consumers about the meaning and importance of R-value, which consumers need to understand R-values, Id. at 50224; (5) sellers had exaggerated the amount of savings on fuel bills that consumers could expect, and often failed to disclose that savings will vary depending on the consumer's particular circumstances, Id.; and (6) sellers had falsely claimed that consumers would qualify for tax credits through the purchase of home insulation, or that products had been "certified" or "favored" by federal agencies, Id.

E. Requirements of the Rule

The Rule requires that manufacturers and others who sell home insulation determine and disclose each product's R-value (and related information -- e.g., thickness, coverage area per package) on package labels and manufacturers' fact sheets. R-value ratings vary among different types and forms of home insulations and among products of the same type and form. The Rule requires that R-value claims to consumers about specific home insulation products be based on uniform R-value test procedures that measure thermal performance under "steady-state" (i.e., "static") conditions.(8) Mass insulation products may be tested under any of the test methods; reflective insulation products must be tested according to either ASTM C 236-89 (1993) or ASTM C 976-90, which can determine the R-values of insulation systems (such as those that include one or more air spaces).(9) The tests must be conducted at a mean temperature of 75 F. The tests on mass insulation products must be conducted on the insulation material alone (excluding any airspace).

When it promulgated the Rule, the Commission found that certain factors, such as aging or settling, affect the thermal performance of home insulation products. 44 FR at 50219-20, 50227-28. To ensure that R-value claims take these factors into account, the Rule mandates that the required R-value tests for polyurethane, polyisocyanurate, and extruded polystyrene insulation products be conducted on test specimens that fully reflect the effect of aging,(10) and for loose-fill insulation products on test specimens that fully reflect the effect of settling.(11)

Specific disclosures must be made: (1) by manufacturers on product labels and manufacturers' fact sheets; (2) by professional installers and new home sellers on receipts or contracts; and (3) by manufacturers, professional installers, and retailers in advertising and other promotional materials (including those on the Internet) that contain an R-value, price, thickness, or energy-savings claim, or compare one type of insulation to another. Manufacturers and other sellers must have a "reasonable basis" for any energy savings claims they make.(12)

IV. DISCUSSION OF COMMENTS, PROPOSED AMENDMENTS, OBJECTIVES, AND REGULATORY ALTERNATIVES

This part of the notice summarizes and discusses the issues raised by the comments, including suggestions that the Commission revise the Rule. In analyzing the comments, the Commission has considered whether the suggested revisions would further the Commission's objective of ensuring that consumers receive information about home insulation products prior to purchase in a uniform, reliable, and substantiated manner, so that they can evaluate how well a particular product is likely to perform and make meaningful, cost-based purchasing decisions. In addition, the Commission has considered alternatives to amending the Rule to impose new requirements on an industry-wide basis, such as dealing with questionable claims or practices on a case-by-case basis, or exploring other mechanisms such as consumer and business education or industry self-regulation. Below, the Commission explains, on an issue-by-issue basis, whether it proposes amending the Rule as suggested by the comments. Both Parts IV and V include specific issues and questions on which the Commission solicits public comments.

A. Disclosing Thermal Performance of Additional Products

1. Residential Pipe and Duct Insulations

Comments

Dr. Kenneth E. Wilkes, for ORNL, recommended amending the Rule to include pipe insulations and all types of duct insulations, and listed the applicable ASTM test methods that apply to these products. Dr. Wilkes stated that the disclosure of R-value information would provide important information for purchasers of these products.(13)

Discussion

The Commission excluded pipe insulation based on uncontroverted evidence in the original rulemaking proceeding that it was used primarily to prevent moisture condensation on low temperature lines, not for energy conservation; that R-value was not a reliable basis for comparing the performance of pipe insulations; and that pipe insulations were not commonly advertised in terms of energy-savings potential.(14) Similarly, it excluded duct insulations other than duct wrap because only duct wrap was used extensively in the residential setting. 44 FR at 50238 n.170. The Commission's staff has reviewed current consumer advertising for these products and found no information to indicate that these facts have changed. Unless interested parties have information that sellers are misrepresenting the thermal performance of these products to consumers, the Commission will not propose extending the Rule to cover them.

2. Non-residential Insulations

Comments

Two comments suggested extending the Rule to cover insulation products used in all buildings, not just residential applications. Dr. David W. Yarbrough, for Tennessee Technological University ("TN Tech."), asserted that extending the Rule to cover commercial building insulations would improve the energy efficiency of buildings and would contribute to the nation's energy conservation effort without imposing a measurable increased cost on manufacturers.(15) Dr. Wilkes, for ORNL, stated that the Rule has improved both the marketplace and the technology for home insulations and contended that similar improvements are needed in the commercial market and would occur if the Rule's coverage were expanded.(16) In contrast, Celotex stated that the Commission should not extend the Rule to cover commercial applications because commercial insulations are purchased primarily by professional architects, engineers, and specification writers.(17)

Discussion

Although applying the Rule to thermal insulation products used in commercial buildings might provide information to purchasers that could improve the energy efficiency of buildings, and otherwise prove useful, the comments do not demonstrate that sellers of commercial insulations are engaged in unfair or deceptive acts or practices that would justify expanding the Rule. Furthermore, in many instances, thermal insulation purchasing decisions for commercial building applications are made by architects or engineers. These professionals may require R-value and other performance information based on circumstances different than the uniform approach the Commission determined was necessary to provide accurate and understandable information to individual consumers to compare competing products and make purchasing decisions.

In limiting the disclosure requirements to materials distributed "for consumer use," the Commission recognized that insulation manufacturers often prepare detailed, technical data for building industry professionals, who should already be informed concerning thermal insulation performance. The Commission also recognized that manufacturers may wish to provide these professionals with additional information or with information in a different form from that required for consumer use. 44 FR at 50225.

For these reasons, the Commission does not propose extending the Rule to cover sales to the commercial market. If interested parties have evidence that sellers in this market are misrepresenting the thermal performance of insulation products or are engaging in other unfair or deceptive practices, however, the Commission invites them to submit this information.

B. Disclosing In-Use Thermal Performance Values

1. Performance of Insulations in Actual Use

Eleven comments discussed seasonal and other variables that can affect the R-value of insulation products in actual use, and suggested that the Rule does not sufficiently account for these factors.(18)

Comments Regarding Factors That Affect Performance in Attics During Winter Conditions

Ten of these comments discussed the reduction in R-value of very low density fibrous insulations (e.g., those at approximately 0.7 pounds per cubic foot or less) installed in open or vented attics that can result from convective currents when the outside temperature (and that in the attic) is particularly low.(19) CIMA stated that when the Rule was promulgated it was assumed that R-value was relatively unchanging over a wide range of temperatures. CIMA asserted that subsequent research by ORNL has shown a reduction of steady-state R-values caused by convective heat loss in very low density fiber insulation materials during very cold periods, when the temperature difference (delta T) between the heated area of a home and its cold attic becomes particularly great. CIMA stated that this phenomenon can reduce the steady-state R-value of affected products from 10% at a delta T of 50 F to 55 F (17 F to 25 F in the attic of a home heated to 72 F) to as much as 40% at a delta T of 90 F (-18 F in the attic of a home heated to 72 F), which can occur during the most severe winter conditions in some portions of the United States. CIMA recommended that the Commission require that insulation manufacturers provide winter design correction factors in coverage charts to compensate for R-value erosion due to convective heat loss, and require that, if insulation material is not subject to R-value loss under cold conditions, the manufacturer state on the package label that the insulation is not subject to convective heat loss at winter attic temperatures above -20 F.(20)

Dr. Wilkes, for ORNL, pointed out that tests on very low density loose-fill fiberglass insulations with an airspace above the insulation (as in an open attic application) gave R-values that decreased by more than 50% from those determined at a mean test temperature of 75 F value, when they were tested with a delta T greater than 72 F and a mean test temperature of 70 F. Dr. Wilkes explained that ASTM is developing a method of determining the thermal performance of attic insulations during winter conditions, ASTM C 1373,(21) and suggested that the Commission incorporate it into the Rule when it is adopted. This method is still under consideration by ASTM.

Mr. Tranmer, for GreenStone, asserted that several factors in addition to R-values that are determined under steady-state conditions have a major effect on product performance, such as air permeability and temperature differential. Mr. Tranmer stated that a measurement known as the Rayleigh number(22) provides a more complete indication of the effect that the combination of R-value, air permeability, and temperature differential have on insulation materials under specific conditions, and that it represents a more accurate measure of insulating capabilities than R-value alone. He suggested that the Commission require the Rayleigh number on packages and promotional materials to give consumers a better measure of the overall effectiveness of insulation products.(23)

Mr. Tranmer also recommended that the Commission specify testing with the ORNL Large Scale Climate Simulator to provide more accurate information for all attic insulation products, and that these products be tested at temperatures from -20F to +120F to provide consumers with performance information specific to a particular climate zone. He stated that, while the cost of testing in this apparatus is approximately $20,000 (significantly more than the usual R-value test), the benefits through increased energy savings would more than offset the increase in testing costs.(24)

Citing research that heating energy consumption can vary 25% to 38% in structures insulated to the same nominal R-value with different insulation materials, CIMA similarly asserted that, by focusing only on R-value, the current Rule has the effect of misleading consumers into thinking that R-value is the only consideration when buying or specifying insulation. Recognizing that presently there is no perfect solution to this dilemma, CIMA suggested that Commission expand the Rule to require manufacturers to disclose Rayleigh numbers for materials under specific conditions. CIMA asserted that the Rayleigh number combines the effects of R-value, air permeability, and temperature difference to produce an expression of relative insulation performance.

Comments Regarding Factors That Affect Performance Under Winter Versus Summer Conditions

One commenter, Superior, contended that the R-value test procedures presently required as the primary means of identifying heat transfer are no longer valid, because they were developed almost exclusively for winter conditions. Superior asserted that, with the post-World War II advent of air conditioning and a higher concern for summer comfort, the primary mode of heat transfer that should be measured is radiant heat. Superior explained that R-value is a component of conductive heat transfer, while radiant heat should be measured by its emissivity,(25) and contended that reflective insulations with one-half or less the steady-state R-value of fiberglass will stop more heat transfer into the home during summer conditions. Superior recommended that the Commission require manufacturers of all insulations to disclose winter and summer performance values, with the summer value determined according to a test procedure other than R-value tests, which have very little significance for radiant heat transfer during summer conditions.(26)

Discussion

The Rule requires that R-values be determined according to ASTM test methods that provide R-value measurements under "steady-state" or "static" laboratory conditions. These test methods do not take into account transient environmental factors, such as air circulation, that can have a significant effect on insulation performance in actual use (i.e., on site, or in situ). When it promulgated the Rule, the Commission determined that, notwithstanding this limitation, these steady-state tests were the most reliable and accurate test methods available. In addition, evidence on the rulemaking record indicated that, although environmental conditions might affect the R-value number determined in steady-state tests, these conditions would affect competing home insulation products in approximately the same manner. Accordingly, the Commission determined that use of the ASTM steady-state R-value test methods would permit fair comparisons of product R-values on a standardized basis to provide consumers with a reliable, uniform, and comparative base for their purchasing decisions. 44 FR at 50225-26. At the same time, while the Rule requires that R-values claimed must be based on the uniform test methods specified in the Rule, manufacturers and other sellers may provide additional, truthful, substantiated information voluntarily to consumers about the manner in which their products perform in actual use.

The Commission recognizes that the testing of insulation products by means of steady-state laboratory testing procedures may not duplicate precisely the performance of an insulation product in situ. The thermal performance of any insulation product in actual use, however, is a highly complex subject that involves a broad range of parameters, including the design characteristics of the building and the specific application in which the product is installed (e.g., open attic, enclosed wall cavity), the geographical location, outside and inside temperatures, air and moisture movement, proper installation, and other variables. Determining and disclosing R-values under these varying circumstances, only some of which may apply to a particular use by a specific consumer, could result in multiple R-value disclosures that might overload rather than assist consumers in comparing insulation products and making purchase decisions. For these reasons, the Commission does not at this time propose specific amendments to require disclosures regarding in situ performance or multiple R-values for different uses.

Consumers, however, could benefit from the most up-to-date, accurate, and useful information, based on the best available research and substantiation. For example, in areas where a significant delta T is predictable, consumers might want to install additional insulation to take into account the reduction in R-value that might occur during extreme conditions, or consider installing a higher density product. The Commission, therefore, solicits comments on the alternatives to steady-state R-values (e.g., Rayleigh numbers, R-value disclosures based on temperature ranges for different regions of the country or for different applications) suggested by the commenters, or other alternatives, that would provide consumers with accurate, meaningful, and understandable information relevant to their individual circumstances. The Commission requests that commenters address: (1) specific alternative measurements that are available to describe the in situ use of home insulation products better than the steady-state R-values required by the Rule; (2) which in situ conditions should be accounted for (and why); (3) whether (and how and to what extent) different types or forms of home insulation products perform differently under specific in situ conditions, and how significant this different performance is under specific circumstances (e.g., how much would the difference in performance in actual use make on the consumer's annual fuel bill); (4) whether accepted test methods are available to measure in situ performance (and the identity of specific test methods); (5) how the results of in situ performance measurements could be described in a meaningful manner to consumers; and (6) the benefits and costs to consumers and sellers that would be associated with the use of the alternatives. Among other things, commenters are requested to include data such as consumer research that demonstrate whether disclosures of in situ performance would be meaningful and understandable to consumers.

2. Performance of Building System Components That Include Insulation

Comments

Four manufacturers of structural insulation panels (building systems products that include insulation as a major component)(27) and a trade association representing such manufacturers(28) supported requiring the thermal efficiency testing of insulation systems, rather than testing only individual insulation products. These comments asserted that the Structural Insulated Panel ("SIP") industry is penalized by reporting R-values of the insulation components as the measure of the thermal efficiency of panel systems because such R-values do not adequately represent the energy efficiency and thermal effectiveness of the panel systems in comparison to insulation installed in conventional (or "stick") construction. Porter, for example, contended that, although some insulated panels may appear to have the same total R-value as some fiberglass batts used in stick construction, "[i]n a typical installation, using EPS foam in a structural insulated panel, the EPS panel outperforms [a] fiberglass batt by 20%."

Three of the manufacturers(29) and the trade association, however, apparently recognized that additional research and development would be necessary before the Commission could require the testing and disclosure of systems performance values. These comments recommended that the Commission, along with several other federal agencies, work with industry to develop consensus testing procedures to consider factors such as air infiltration, thermal bridging, and moisture effects on the performance of building systems, and provide resources for testing and evaluation of the thermal performance and energy efficiency of construction systems.

Discussion

The Rule covers home insulation products, including products made up of home insulation and other components (such as structural insulation panels) when they are marketed primarily to slow down the flow of heat. These comments appear to be concerned primarily that the Rule may penalize them by requiring that they disclose the R-value of the insulation component of their panels, instead of the thermal performance of their panels compared to the use of competing home insulation products in other types of building construction. Although the Rule requires that those who market home insulation test and disclose the R-value of their home insulation, it does not restrict sellers from providing additional information about how their products perform in actual use, if they are able to substantiate their claims. The comments acknowledge that additional research would be required to develop the procedures necessary to implement a requirement that sellers include in their R-value disclosures information about how their products perform in various types of construction, which would depend on multiple variables. Even if such procedures were developed, as a practical matter, it might be extremely difficult, and perhaps impossible, to draft testing and disclosure requirements that could take such variables into account in a manner that would be meaningful to consumers, and where the benefits (e.g., better information for consumers) outweighed the additional costs (e.g., for additional testing and disclosures) that would be imposed.

Accordingly, while the Commission acknowledges the concerns underlying these comments, it has determined not to propose amending the Rule at this time to require the disclosure of insulation performance based on testing of home insulation products in different types of applications. The Commission encourages interested parties to pursue the additional testing and research that would support a system-type disclosure format, and the Commission's staff is available to provide advice about the type of documentation that would be necessary for the Commission to propose formal testing and disclosure requirements that include these applications.

C. Disclosing R-values that Account for Factors Affecting R-value

The comments described in this section addressed issues relating to the Rule's R-value test specimen preparation requirements for specific types and forms of home insulation products. All home insulation products are covered by the Rule, regardless of whether they are specifically referred to in the test specimen preparation requirements or other provisions of the Rule. That is, they must be tested for R-value under the test procedures specified in section 460.5 of the Rule and the R-value results of those tests must be disclosed to consumers. In some instances the Rule specifies how test specimens must be prepared for R-value tests. In other instances it does not, either because the Commission determined it was not necessary to specify R-value test specimen preparation requirements, or because those products were not being sold when the Commission conducted the original rulemaking. These comments suggested adopting updated test specimen preparation requirements or specifying test specimen preparation requirements not currently required by the Rule.(30)

1. Aging

a. Cellular Plastics Insulations

Certain types of cellular plastics insulations (polyurethane, polyisocyanurate, extruded polystyrene boardstock insulations) are manufactured in a process that results in a gas other than normal air being incorporated into the voids in the products. This gives the product an initial R-value higher than it would have if it contained normal air (as do other types of insulations). A chemical process, known as aging, causes the R-value of these insulations to decrease over time as the gas is replaced by normal air. 44 FR at 50219-20. The length of this aging process, which may continue over several years, depends on whether the product is faced or unfaced, the permeability of the facing, how well the facing adheres to the product, and other factors.

The Rule addresses this aging process by requiring that R-value tests be performed on specimens that "fully reflect the effect of aging on the product's R-value." Section 460.5(a)(1) of the Rule accepts the use of the "accelerated aging" procedure in General Services Administration ("GSA") purchase Specification HH-I-530A (which was in effect at the time the Commission promulgated the Rule) as a permissible "safe harbor" procedure, but also allows manufacturers to use "another reliable procedure." 44 FR at 50227-28. The "accelerated" procedure was designed to age these insulations in a shorter period than they would age under normal usage conditions. Under the "accelerated aging" method in the GSA specification, test specimens are aged for 90 days at 140 F dry heat.

GSA amended its specification in 1982 to allow the use of an optional aging procedure (in addition to the "accelerated" method) under which test specimens are aged for six months at 73 F + 4 F and 50 percent + 5 percent relative humidity (with air circulation to expose all surfaces to the surrounding environmental conditions). An industry group, the Roof Insulation Committee of the Thermal Insulation Manufacturers Association ("RIC/TIMA"), specified the use of similar conditions in a technical bulletin it adopted at about the same time. In response to adoption of the alternative aging procedure by GSA and RIC/TIMA, the Commission's staff advised home insulation sellers that the alternative procedure appeared to be reliable and could be used to age cellular plastics insulations. The staff cautioned, however, that manufacturers of insulations faced with materials that significantly retard aging may need to age test specimens for a longer period of time, and that the staff would consider whether the alternative procedure was acceptable for specific products on a case-by-case basis.(31)

Comments Regarding Which Aging Procedures Should Be Required

Ten comments addressed how the Rule should treat the reduction in R-values that occurs when cellular plastics insulation products age.(32) Two recommended requiring the use of aging procedures in current ASTM specifications; one recommended requiring the use of a different method being developed by ASTM; and one association (representing 37 manufacturers) and two manufacturers appear to question the accuracy of current aging procedures in determining long-term performance.

Celotex and PIMA(33) recommended deleting the reference to the aging procedures in former GSA Specification HH-I-530A and instead requiring the use of the aging procedures in ASTM C 1289-95 (for faced polyisocyanurate and faced polyurethane),(34) ASTM C 591-85 (for unfaced polyisocyanurate and unfaced polyurethane),(35) and ASTM C 578-92 (for polystyrene).(36) The aging procedures in these ASTM specifications are essentially the same as the optional procedures contained in the revised GSA specification, although ASTM C 591-94 specifies that aging must be conducted according to the 180-day procedure.

Dr. Wilkes, for ORNL, stated that the Rule's aging requirement should be improved and modified to account for technological changes. He reported that ASTM was developing a new method of determining the aged R-value of unfaced cellular plastics board stock insulations and those with permeable facings based on R-value tests of thin samples sliced from the center of the boards (which ASTM has now adopted as ASTM C 1303-95).(37) Under this method, a thin test specimen is sliced from close to the center of the insulation board. R-value measurements are taken over time, normally a 180-day period, and the test specimen is kept in an environmental chamber when R-value tests are not being conducted. The resulting R-values over time are converted into an average value according to a specific mathematical formula. Dr. Wilkes recommended that the Commission adopt this ASTM method as the required procedure for deriving aged R-values for these insulation products.

Dr. Wilkes asserted that a satisfactory aging method for these boardstock insulations with impermeable facers (e.g., aluminum) has not yet been developed. He recommended that the Rule state this fact and require "direct" aging of products with impermeable facers (i.e., aging over time of samples as they are produced -- at full thickness and with facers attached). Finally, Dr. Wilkes recommended that the Commission delete the phrase "or another reliable procedure" because of its lack of specificity.(38)

AMF, for itself and its 37 manufacturing partners, stated that the reporting of different R-values for insulations that use gases, and that are known to lose R-value over time as those gases diffuse, has frustrated the original objective of the Rule to provide a "level playing field."(39) Plymouth Foam Products complained that "[s]ome [cellular plastics] foam insulation manufacturers are allowed to represent their products with installed R-values of as high as eight per inch, when, in fact, that value will reduce substantially over the life of the product/structure."(40) These comments recommended that the Rule require testing and disclosure of R-values that more accurately reflect the effect of aging on the R-value of cellular plastics insulation products.

Big Sky and Western contended that the practice of aging a test specimen for six months, even at an elevated temperature, does not provide a true picture of the R-value a consumer can expect over the full life of the product.(41) Big Sky suggested three options: (1) a six-month accelerated aging process, with an additional 18-month hold on the test specimens before they are tested for R-value; (2) accelerated aging for 18 months; or (3) holding the test specimens for three years. Western suggested that the Commission adopt an accelerated aging test either from ASTM methods or the Corps of Engineers System.

Discussion Regarding Which Aging Procedures Should Be Required

Requiring manufacturers to age their insulation products for several years before being able to test and market them would impose a significant burden. Instead, the Rule allows the use of the GSA "accelerated aging" procedure, or another reliable procedure. Because some of the comments question whether the GSA accelerated aging procedure or the procedures in ASTM specifications are adequate for all types of cellular plastics insulation products (particularly those with less permeable facers), the Commission solicits comments regarding the length of time over which specific types and forms of cellular plastics insulations age (including both unfaced products and those with different kinds of facings); the effect of the aging process on specific types and forms of cellular plastics insulations (i.e., the overall reduction of R-value over time); the accuracy of different aging procedures to reflect long-term aging of specific types and forms of cellular plastics insulation products; which aging procedures the Commission should require for which types of cellular plastics insulation products; the burdens that would be imposed on manufacturers and other sellers by requiring the use of specific aging procedures; and how the Commission should deal with products for which adequate aging procedures do not currently exist (e.g., those with relatively non-permeable facings).

Comments Regarding Which Cellular Plastics Insulations Should Be Aged for R-value Testing

NAIMA recommended requiring R-value testing on aged samples of "other foam plastic insulation" products (in addition to the types currently enumerated) and recordkeeping of the age of the test specimen. NAIMA asserted that present and future foam insulations not currently covered by the aging requirement should be tested and labeled to reflect the effects of aging, but did not submit data to demonstrate whether other existing cellular plastics, or foam, insulations are subject to aging. According to NAIMA, the requirement would impose no extra testing or labeling burdens on manufacturers of insulations that are not subject to aging.(42)

Discussion Regarding Which Cellular Plastics Insulations Should Be Aged for R-value Testing

The Commission required R-value testing of aged specimens only for extruded polystyrene, polyurethane, and polyisocyanurate insulations because these were the only types of insulations discussed during the rulemaking proceeding that included blowing agents subject to the aging process. The Commission agrees that manufacturers of additional types of cellular plastics, or foam, insulations that are subject to the aging process should be required to test aged specimens and disclose aged R-values, and to maintain testing records identifying the aging procedure used. The Commission, therefore, solicits comments on what additional types or forms of insulations are subject to the aging process.

b. Reflective Insulations

Comments

NAIMA recommended that the Commission require that reflective (aluminum foil) insulation products be tested for emissivity and R-value "using samples that fully reflect the effect of aging" on the product's emissivity and R-value. NAIMA asserted that thermal performance claims for reflective insulations, as for cellular plastics insulations, should reflect the effects of aging (in this case, the accumulation of dust or corrosion of the foil). NAIMA did not submit evidence that dusting or corrosion is a problem that degrades the R-value of reflective insulations in actual applications, and did not suggest a specific test method or procedure that should be used to determine the effects of this type of aging on reflective insulations.(43)

Discussion

The Commission believes that claims for all types of home insulation products should take into account factors that affect the products' thermal performance. The Commission, therefore, invites interested parties to comment on whether dusting or corrosion of reflective insulations in actual applications is a problem resulting in lower R-values than claimed, the extent of any degradation of R-value, and how the effect of dusting or corrosion on R-value could most accurately be determined.

2. Settling

a. Loose-fill and Stabilized Insulations in Attics

In the original rulemaking proceeding, the Commission determined that all dry-applied loose-fill insulation products tend to settle after being installed in open (or unconfined) areas such as attics. Settling lowers the product's thickness, increases its density, and affects its total R-value.(44) The amount of settling depends on several factors, including the raw materials and manufacturing process used, and the installer's application techniques (which affect the insulation's initial thickness and density).

To ensure that claims made to consumers are based on long-term thickness and density after settling, the Rule requires that the R-value of each dry-applied loose-fill home insulation product for these applications be determined at its "settled density." The Rule requires that manufacturers of dry-applied loose-fill cellulose insulation for attic applications test and disclose the R-value (as well as coverage area and related information) at the long-term, settled density determined according to paragraph 8 of ASTM C 739-91, commonly referred to as the "Blower Cyclone Shaker" ("BCS") test.(45) Because a consensus-based test procedure had not been adopted for determining the long-term, settled density of dry-applied loose-fill mineral-fiber insulation for this type of application, the Rule does not specify the procedure for determining the density of the R-value test specimen, but it requires that R-values claimed to consumers be based on long-term thickness and density after settling.(46)

Since the Commission promulgated the Rule, new forms of loose-fill-type home insulation products have been introduced for use in attic applications, including "stabilized" cellulose. "Stabilized" cellulose refers to a form of loose-fill cellulose insulation that contains a glue binder and is applied on attic floors with a small amount of liquid. Application of the insulation with the glue binder and liquid purportedly results in lower-density cellulose insulations that do not settle like dry-applied loose-fill cellulose insulations. The Rule does not currently specify a procedure for determining the long-term, settled density of stabilized cellulose insulation.

Comments

Dry-applied Loose-fill Cellulose. Dr. Wilkes, for ORNL, stated that settling decreases the R-value obtained when a loose-fill insulation product is applied, although limited information exists about the amount of settling that occurs. Dr. Wilkes supported use of the BCS test procedure to determine the settled density of dry-applied loose-fill cellulose insulation. He suggested that the BCS procedure may be inappropriate for new products such as those with initial densities as low as 1.0 to 1.5 pounds per cubic foot. For such products, Dr. Wilkes stated that in situ data would be more appropriate than the BCS procedure in determining long-term, settled density, and recommended that the Commission permit manufacturers to submit in-situ data to demonstrate the actual settled density of their products.(47)

Dry-applied Loose-fill Mineral Fiber. Eleven comments addressed how the settled density of dry-applied loose-fill mineral fiber insulation products in open attic applications should be determined for R-value testing.(48) Regal contended that the Rule's objective of creating a level playing field has been compromised because of the failure of GSA, ASTM, and the mineral fiber industry to develop a uniform standard for determining the settled density of dry-applied loose-fill mineral fiber insulations.(49) Other comments agreed.(50) Three stated that this uneven playing field (i.e., requiring cellulose manufacturers, but not mineral fiber manufacturers, to use a specific test procedure) imposes a competitive disadvantage for the cellulose industry.(51) CIMA, for example, stated that the BCS test typically produces 30% settling for loose-fill cellulose, while long-term studies of actual installations rarely find cellulose settling as much as 20%. CIMA asserted that the Rule places the cellulose industry at a competitive disadvantage of as much as 10% to 15% compared to loose-fill fiberglass, and that, if this discrimination has affected the cellulose market share by as little as 5%, it has resulted in an annual revenue loss of approximately $50 million for cellulose producers.

Four comments stated this uneven treatment is unfair to consumers.(52) GreenStone/Smith, for example, stated that mineral fiber manufacturers have not developed a standard test method to measure the settling of loose-fill mineral fiber insulations, but instead claim that if their products are installed at the density they recommend, the amount of settling will be minimal (less than 5%). He asserted that the mineral fiber manufacturers construct coverage charts at this density and represent to consumers that no settling is expected. According to GreenStone/Smith, installers who desire to minimize costs can install loose-fill mineral fiber insulations at less than the density claimed by manufacturers (and at a lower total R-value than claimed), without consumers' knowledge, and thereby save time and material and defraud consumers of the energy savings they anticipate.

As a short-term solution, five comments recommended that the Commission impose a settlement factor of up to 10% or more for dry-applied loose-fill mineral insulation products, pending the adoption of a suitable industry standard to address how much these products settle.(53) Dr. Yarbrough, for TN Tech., and Dr. Wilkes, for ORNL, suggested that, until a uniform test procedure is developed, manufacturers should determine settled density based on in situ data.(54)

Stabilized Cellulose. Dr. Wilkes, for ORNL,(55) and Dr. Yarbrough, for TN Tech.,(56) stated that the BCS test is inappropriate for determining the settled density of stabilized cellulose insulation. Dr. Yarbrough explained that "stabilized" cellulose insulation contains a binder, or other means, for bonding particles in the insulation to reduce settling, and that the fan used in the BCS test breaks the bond. Dr. Wilkes and Dr. Yarbrough recommended allowing the use of in situ observations of the degree of settling to establish the settled density at which the R-value of a stabilized cellulose product must be determined. Dr. Yarbrough stated that a methodology for obtaining in situ data is available.(57) He explained that an ASTM task group is working on a material specification for stabilized cellulose insulation that he expects will include a method for determining settled density, and recommended that the Commission consider requiring the use of the ASTM standard when it has been adopted by ASTM.(58)

NAIMA recommended requiring that R-value tests on stabilized cellulose insulations be "done on samples that fully reflect the effect of settling on the product's R-value." NAIMA stated that ASTM C 1149(59) has been modified to include products containing an adhesive that is mixed with water during installation and is intended for use in attic applications. NAIMA stated that a task group is developing a method to determine and quantify the amount of settling.(60)

Discussion

Dry-applied Loose-fill Cellulose. Although the Rule requires manufacturers of dry-applied loose-fill cellulose to determine the R-values and coverages of their products at the settled density determined according to the BCS procedure, manufacturers who can demonstrate that the BCS procedure is inappropriate for their products can petition the Commission for an exemption that would allow them to determine the settled density of their products according to a more appropriate method. See note 30, above.

Dry-Applied Loose-fill Mineral Fiber. The Rule specifies the procedures to be used in determining the settled density only for cellulosic, and not mineral fiber, insulation products. When the Commission promulgated the Rule in 1979, it expected that GSA soon would adopt a specific test procedure for determining the settled density of dry-applied loose-fill mineral fiber insulation products. 44 FR at 50228, 50239 n.239. GSA did not do so, and now accepts the use of ASTM standards, which do not specify procedures for determining the settled density of dry-applied loose-fill mineral fiber insulations.

Reports of studies conducted by Oak Ridge National Laboratory during the 1980s demonstrate that certain loose-fill mineral fiber insulation products can settle following installation, resulting in a reduction of R-value.(61) The results differed in the amount of settling, and the effect of settling on the R-values of the specific insulation products studied, depending on the type of mineral fiber insulations studied (fiberglass versus rock wool products) due to differences in density.

The Commission agrees that it would be preferable to specify a uniform procedure for determining the long-term, settled density of dry-applied loose-fill mineral fiber insulation products. Unfortunately, none of the comments suggested a specific procedure that the Commission could adopt at this time. In addition, the comments that suggested requiring an across-the-board settlement factor of 10% have not submitted documentation that would justify the Commission imposing it on all dry-applied loose-fill mineral fiber insulation products.

The Commission, therefore, solicits comments on specific reliable and uniform procedures that would be appropriate for determining the long-term, settled density of dry-applied loose-fill mineral fiber insulation products, and the submission of data to demonstrate that those procedures will result in uniform and accurate results. For example, the Commission requests any data that demonstrate that any of the following, currently available test procedures, or others, would produce accurate and reliable, long-term settled density results for mineral fiber insulation products in attic applications: the BCS test procedure in ASTM C 739-91 (which currently is required for dry-applied, loose-fill cellulose insulation products); the "Canadian drop box procedure," which previously was proposed by GSA for loose-fill mineral fiber insulations under Federal Specification HH-I-1030B;(62) the British Standard Vibration Test; and the procedure developed in Scandinavia by Dr. Svennerstedt. In the meantime, the Commission will continue to examine the data specific manufacturers use to substantiate their R-value, long-term settled density, and coverage claims.

Stabilized Cellulose. Because of the manner in which stabilized cellulose insulation is installed, the Commission agrees that the BCS test procedure may not be appropriate for determining its long-term, settled density. Further, the Commission does not believe that the procedure for determining density in ASTM C 1149, which NAIMA suggested, is the appropriate measure of the long-term, settled density of stabilized cellulose insulations installed in attic applications. ASTM C 1149 is designed for insulations sprayed onto walls (most often being applied to metal walls in commercial buildings, where they are left exposed, without being covered by an internal wall), and requires that these insulations be able to support themselves in that type of application. The settling characteristics of stabilized cellulose insulations in attic applications are different from those of self-supported insulations sprayed onto walls. ASTM has not yet adopted a specific method for determining the long-term density of stabilized cellulose insulation for attic applications. When ASTM, or others, adopt an appropriate procedure, the Commission will consider whether to require its use. In the meantime, under section 5 of the FTC Act, manufacturers must have a reasonable basis for the density at which they conduct the R-value tests required by the Rule and make R-value claims to consumers.

Loose-fill and Stabilized Insulations Used in Manufactured Housing Attics. No comments addressed whether the procedures currently used to determine the settled density of dry-applied loose-fill insulations or stabilized insulations when they are used in attics of site-built homes are appropriate for determining their settled density when they are used in attics of manufactured housing. Industry members have raised this question separately, however, with the Commission's staff. At issue is whether these insulations, which are installed in attic assemblies in a factory and then transported to the site where the manufactured home will be located, settle more, or differently, than those used in site-built homes because of additional vibrations and other factors during transportation. The Commission solicits comments regarding the extent of settling of dry-applied loose-fill insulations and stabilized insulations when they are used in attics of manufactured housing, the density at which the R-value of these insulations should be determined for use in attics of manufactured housing, and how that density should be determined.

b. Loose-fill and Self-supported Insulations in Walls

Dry-applied loose-fill insulations and spray-applied, self-supported insulations can be installed in walls in residential applications. Dry-applied loose-fill insulations normally can only be applied to existing wall cavities (primarily in retrofit applications). Spray-applied, self-supported insulations can be applied to open wall cavities before installation of internal walls.

Dry-applied loose-fill insulations may settle when blown into a confined area, such as an enclosed wall cavity, leaving a gap at the top of the wall cavity if they are not sufficiently compressed during installation. Manufacturers who claim an R-value for a dry-applied loose-fill insulation must disclose the R-value at the applied density, determined according to the R-value test procedures specified in the Rule. The Rule, however, does not specify how manufacturers must determine that density because there was no standard procedure for measuring the applied density in wall applications for all products at the time the Commission promulgated the Rule. Because dry-applied loose-fill insulations installed in closed wall cavities must be compressed during application to ensure that they do not settle, the applied density in wall applications is likely to be greater than the settled density of the product when it is installed in an open attic.

Self-supported, spray-applied insulations, mixed with water and adhesives (also referred to as "wet-spray" insulations), are installed pneumatically on-site by professional installers. They may be made of either cellulose or mineral fiber. When applied, this form of insulation requires no support other than the insulation itself or the substrate to which it is attached. These products most often are used in walls in commercial applications, where they may be left exposed after they are installed. They are rarely used in residences, primarily because this application requires the use of more insulation material for a given thickness (i.e., the insulation is installed at a higher density and cost), often without any increase in total R-value, and sometimes at a reduced R-value. They are not used in attics because of their additional weight (and cost). Because these products are applied at a greater density than either dry-applied loose-fill or stabilized insulations, they are not likely to settle. Although this form of insulation was not discussed during the original rulemaking proceeding and the Rule does not specify how R-value test specimens must be prepared, it is covered by the Rule if it is sold for use in the residential market. Because the density at which these insulations are applied affects their R-values, the Commission's staff has advised industry members that they should prepare test specimens according to the manufacturer's installation instructions, using equipment, materials, and procedures representative of the manner in which the insulation is applied in the field.

Comments Regarding the Use of Dry-applied Loose-fill Insulations in Wall Cavities

Two comments recommended requiring the disclosure of R-values and related information for loose-fill insulations intended to be installed in walls or other enclosed cavities. NAIMA recommended requiring that coverage charts for these products include R-values, maximum net coverage area, and minimum weight per square foot for the thicknesses of common cavities (e.g., 3-1/2"). NAIMA asserted that separate disclosures for installations of these insulation products in enclosed cavities is necessary to provide guidance about the proper amount of material that must be installed.(63) Mr. Smith, for GreenStone, agreed and suggested requiring disclosure of a coverage chart for "Gross Coverage," for cavities using 2x4 and 2x6 on 16" center construction. He recommended requiring the disclosure of the density at which the loose-fill insulation should be installed, along with a statement that applications below this density may be subject to settling and may create gaps at the top of or within wall cavities that may significantly reduce the insulating value of the product. Lastly, he stated that the R-value for each of the wall thicknesses claimed must be determined at the applied density the manufacturer recommends.(64)

Discussion Regarding the Use of Dry-applied Loose-fill Insulations in Wall Cavities

The Commission agrees that specific requirements for determining the appropriate density for the R-value test specimen and for disclosures on coverage charts for applications in enclosed wall cavities would be appropriate and desirable. GreenStone's suggestion of requiring a statement of "applied density" could provide helpful information to installers in determining whether they have installed the requisite amount of insulation material, but it does not address how that density should be determined. The Commission, therefore, solicits comments on whether there are reliable procedures that could be used to determine the density of dry-applied loose-fill insulations when installed in enclosed wall cavities, and the specific disclosures that should be required (e.g., how coverage area for enclosed wall cavities should be described).

Comments Regarding the Use of Self-Supported Insulations in Wall Cavities

ECI recommended adopting the test specimen preparation procedures in ASTM C 1149 when testing insulations that are sprayed into wall cavities.(65) England recommended requiring use of either HUD UM-80(66) or ASTM C 1149, both of which apply to spray-applied cellulose insulation, to ensure that R-value and related information is accurate.(67)

Discussion Regarding the Use of Self-supported Insulations in Wall Cavities

The procedures in paragraph 5.1 of ASTM C 1149-90 and in paragraph 9.1.1 of HUD UM-80, which require that R-value test specimens be prepared using the manufacturer's recommended equipment and procedures and at the manufacturer's maximum recommended thickness, appear to be appropriate procedures for preparing R-value test specimens of self-supported, spray-applied cellulose insulation products. Accordingly, the Commission proposes amending the Rule to require preparation of R-value test specimens of self-supported, spray-applied cellulose insulation products according to either of these specifications. The Commission solicits public comments regarding the accuracy and reliability of the two procedures, whether the Commission should allow use of either procedure or only one, how the Commission should define specifically the products to which the procedures apply, and whether the same procedures (or others) should be required for other types of spray-applied insulations (e.g., mineral fiber insulations) that are used in residential applications.

Discussion Regarding the Use of Loose-fill Insulations and Self-supported Insulations in Wall Cavities of Manufactured Housing

No comment addressed whether the procedures currently used to determine the settled density of dry-applied loose-fill insulations or self-supported insulations when they are used in wall cavities of site-built homes are appropriate for determining their settled density when they are used in wall cavities of manufactured housing. Industry members have raised this question separately, however, with the Commission's staff. At issue is whether the settling of these insulations, which are installed in wall assemblies in a factory and then transported to the site where the manufactured home will be located, settle more, or differently, than those used in site-built homes because of additional vibrations and other factors during transportation. The Commission solicits comments regarding the extent of settling of dry-applied loose-fill insulations and self-supported insulations when they are used in wall cavities of manufactured housing, the density at which the R-value of these insulations should be determined for use in wall cavities of manufactured housing, and how that density should be determined.

3. Density Variations

The Rule's testing and labeling requirements assume that the long-term settled density of a dry-applied loose-fill insulation product does not change with variations in thickness. The Rule, therefore, simply requires that manufacturers of dry-applied loose-fill cellulose insulation determine the settled density of each product according to the BCS test procedure and test it for R-value at that density, and that manufacturers of dry-applied loose-fill mineral fiber insulation determine the R-value of each product on samples that fully reflect the effect of settling on R-value. As long as the R-value test has been conducted at that density and at the product's "representative thickness,"(68) the manufacturer can construct the required coverage chart for various total R-value levels based on the R-value result at the tested density.

Comments

Ivan Smith, for GreenStone, recommended revising section 460.6 of the Rule to require testing of loose-fill insulations at each thickness shown on a label unless there is a limitation caused by the physical constraints of the test equipment. Mr. Smith believes it is likely that density will be different at each different thickness of loose-fill material, and that this variation of density potentially affects the thickness necessary to obtain the claimed total R-value. He contended that this requirement would not result in a substantial expense to the manufacturer.(69)

Discussion

The Commission cannot determine whether it would be appropriate to propose amending the Rule as Mr. Smith recommended without specific data to demonstrate whether or how much the density of particular types of loose-fill insulations varies with differences in thickness. The Commission solicits comments and data, therefore, on whether, and how much, the density of specific loose-fill insulations varies with thickness, the effect of any such variations on the total R-value at different thicknesses, and how the Commission should amend the Rule to ensure that R-values and related claims for loose-fill insulation products are accurate.

4. Installation in Closed Cavities of Variable Thickness

Comments

Dr. Yarbrough, for TN Tech, stated that the evaluation of the thermal performance of insulations used in attics of manufactured housing represents a special challenge because, in some cases, the roof cavity (and the insulation installed in it) varies in thickness and density. For example, these roof cavities often slope to the edge of the roof assembly, where the cavity may be only 1½" to 2" thick. Any insulation (whether it is a batt or blanket, dry-applied loose-fill, or stabilized product) installed in such an application can vary in thickness across the cavity, and may be compressed more than normal in the thinnest portions of the cavity. These factors result in different total R-values at different places. Dr. Yarbrough recommended specifying how R-values for such variable thickness and density applications should be calculated, and suggested using a method such as the one he and others have described in a paper published by the American Society of Mechanical Engineers.(70) He stated that the manner in which R-values are expressed for this type of application could affect a major portion of new manufactured homes and could determine whether insulations installed in these applications achieve the total R-values claimed.(71)

Discussion

The Commission agrees that it is important to address how R-values should be determined and disclosed to consumers where the insulation varies in thickness and/or density in particular applications, so that R-values claimed to consumers under these circumstances will be accurate and determined according to a uniform standard. The Commission solicits comments, therefore, regarding the method (such as that recommended by Dr. Yarbrough) that should be used to determine and disclose R-values under these circumstances, and how different variables (e.g., thickness, density) should be accounted for in the determination.

D. Other Testing Requirements

1. Accreditation of Testing Laboratories

Comments

The Celotex Corporation recommended requiring that testing laboratories either be accredited by the National Voluntary Laboratory Accreditation Program ("NVLAP"), administered by the U.S. Department of Commerce's National Institute of Standards and Technology ("NIST), for the specific test methods listed in the Rule, or by the International Organization for Standardization ("ISO") as an ISO/IEC Guide 25 Testing Laboratory. Further, Celotex stated that accreditation as an ISO/IEC Guide 25 Laboratory provides global acceptance of a laboratory's test results.(72)

Discussion

Although accreditation of testing laboratories by a qualified, professional accreditation program generally is useful and important, the Commission is not aware of any significant testing problems with unaccredited laboratories that would justify the Commission's imposing this additional burden under the Rule. Further, to the extent that accreditation of a laboratory provides either domestic or global acceptance of that laboratory's test results, manufacturers and other sellers should already have sufficient incentive to use accredited laboratories, and testing laboratories should have sufficient incentive to seek accreditation, without the Commission imposing an accreditation requirement.

The Rule already includes several interrelated safeguards to ensure testing integrity that make a separate accreditation requirement unnecessary, absent evidence of testing abuse. First, the Rule requires manufacturers to test or have their products tested to substantiate the R-values they claim, and to maintain specific records concerning the testing methods and results. Second, it enables the Commission to analyze the substantiation tests by evaluating the required testing records. Third, it includes a quality control requirement, under which industry members must ensure that the R-value of the insulation they sell is not more than 10% below the R-value they claim. Thus, even if the manufacturer or other covered party has a test result that purports to verify the claimed R-value, the Commission can obtain samples and conduct its own testing to ensure that accurate, properly determined R-values are being disclosed to consumers.

Although the Commission is not proposing to require laboratory accreditation at this time, it solicits comments on the extent to which manufacturers presently use accredited versus nonaccredited labs. In addition, the Commission seeks comments on whether it should require additional recordkeeping to make the records more clearly demonstrate whether the tests have been conducted accurately and in accordance with the required procedures.

2. Test Temperature Requirements

Several test temperature parameters are involved in R-value testing: (1) the temperature on the cold side of the testing apparatus; (2) the temperature on the hot side of the testing apparatus; (3) the mean (or average) test temperature within the test chamber; and (4) the temperature differential (i.e., the temperature spread between the cold and hot sides). The record in the original rulemaking proceeding indicated that variations in these test parameters affected the ASTM steady-state R-value results for mass insulations and reflective insulations differently.

For mass insulations, the record indicated that R-values decreased as the mean test temperature rose, and that this inverse relationship between R-value and mean test temperature was approximately the same for all mass insulations. On the other hand, the record indicated that variations in the temperature differential between the hot and cold sides did not significantly affect the R-value results. For these reasons and others explained below, the Commission determined that R-value tests of mass insulations should be conducted at a mean test temperature of 75 F, but that it was not necessary to specify a required test temperature differential for testing mass insulations.

For traditional reflective foil insulations, on the other hand, the record indicated that variations in mean test temperature did not affect the R-value results, but that variations in the temperature differential between the hot and cold sides did affect the R-value results. At least at smaller temperature differentials, the record indicated that there was an inverse relationship between R-value and the temperature differential; as the temperature differential increased, the R-value result went down. The Commission determined, therefore, that it was necessary to specify both the mean test temperature and the temperature differential for R-value testing of reflective insulations.

The R-value of a reflective insulation is related to its emissivity.(73) Based on evidence that single-sheet reflective foil insulation products with a given emissivity installed in an airspace of the same thickness and configuration will have the same R-value, the Commission minimized manufacturers' testing burdens by allowing them to use the R-values for those products listed in a specific table published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. ("ASHRAE"). Thus, manufacturers of single-sheet reflective insulation products need only to measure the product's emissivity according to a specific ASTM test procedure (or an alternative procedure that provides comparable results)(74) and find the appropriate R-value in the ASHRAE table for that emissivity.(75) The ASHRAE table contained R-values for only certain mean test temperatures and temperature differentials. To ensure that claims were based, to the extent possible, on a standard that would allow comparison on a uniform basis of R-values for single-sheet reflective insulations and mass insulations, the Commission specified that single-sheet reflective insulation manufacturers must use the R-value in the ASHRAE table for a mean test temperature of 50 F (the table did not include a mean test temperature of 75 F, so the Commission selected the mean test temperature closest to 75 F ) and a temperature differential of 30 F.

For multi-sheet reflective foil insulations (used to create multiple airspaces), the record indicated that extrapolation of a total R-value from the ASHRAE R-value for a single airspace was unreliable. 44 FR at 50228. The Commission, therefore, required that R-values be determined through R-value testing according to specific ASTM procedures. So that the results of these tests would be comparable to those for single-sheet insulations and for mass insulations, the Commission determined that the tests must be conducted at a mean test temperature of 75 F and a temperature differential of 30 F.

a. Mean Temperature

Comments

Plymouth Foam Products asserted that a mean test temperature of 40 F would more accurately represent the climate(s) for the majority of the United States than the required 75 F mean test temperature.(76)

Discussion

The Commission addressed this issue when it originally promulgated the Rule.(77) To ensure that R-values claimed to consumers are made on a uniform basis, the Commission required that R-values disclosed to consumers be based on steady-state ASTM R-value tests conducted at a mean temperature of 75 F. The Commission concluded that 75 F (which was incorporated in many voluntary industry standards and federal procurement specifications) would be as effective as any other mean temperature in providing a standard mean test temperature for R-value comparison purposes, although it otherwise had no particular advantage over any other temperature. By requiring that R-value testing be conducted at this mean test temperature, the Commission did not intend to specify a mean test temperature that would be representative of any particular geographical region, or particular season, or of actual performance conditions. Indeed, the Commission concluded that requiring sellers to test and disclose R-values at a mean temperature representative of any specific geographical region, or season of the year, would yield R-value results that would be inappropriate for other regions or seasons. Further, it concluded that requiring sellers to test and disclose R-values separately for different regions or seasons would yield multiple disclosures that could confuse consumers and discourage them from using R-values in making purchasing decisions. Thus, the Commission selected a single mean test temperature to establish a uniform standard for disclosing R-values. Although the Commission received no new information that would indicate that any other single mean test temperature would be preferable to 75 F, the Commission invites public comments on this issue, along with comments regarding the testing and disclosure of in situ performance information. See also the discussion in Part IV.B.1, above.

b. Temperature Differential

Comments

One comment recommended amending the Rule to specify the temperature differential. NAIMA recommended requiring not only that R-value tests be performed at the mean temperature of 75 F, but also requiring a test temperature differential of "50F + 10 F." NAIMA explained that the thermal properties of a specimen may change both with mean temperature and with the temperature difference across the test specimen, and that data and information at standard temperatures are therefore necessary for valid comparison of thermal properties. NAIMA stated that ASTM C 1058(78) specifies a temperature difference of 50F + 10 F when conducting tests at a mean temperature of 75 F according to ASTM test methods C 177, C 236, C 518, and C 1114.(79)

Discussion

The Commission agrees that, if current evidence demonstrates that different test temperature differentials affect R-value results, it may be appropriate to consider specifying a test temperature differential in the Rule to ensure the comparability of R-value claims for competing home insulation products. The Commission, therefore, solicits comments on whether, to what extent, and for what types and forms of insulation, variations in the test temperature differential affect R-value results; and what specific test temperature differential(s) the Commission should impose for tests conducted according to each of the R-value test procedures cited in the Rule. See also the discussion in Part IV.B.1, above.

3. Tolerance

Comments Regarding Responsibilities of Manufacturers Versus Installers

NAIMA(80) and ICAA(81) proposed limiting application of the Rule's 10% tolerance limit to manufacturers by replacing the words "industry member" with "manufacturer."

Discussion Regarding Responsibilities of Manufacturers Versus Installers

The Commission designed the tolerance limit provision to apply to the manufacturer. Strictly speaking, the tolerance does not apply to professional installers or new home sellers. The Rule requires that professional installers and new home sellers apply loose-fill insulations according to the manufacturer's installation instructions, but allows them to rely on the accuracy of the manufacturer's R-value and installation instructions. Installers and new home sellers therefore have the benefit of the 10% tolerance limit for variances occurring in the manufacturing process. But the tolerance is not intended to allow installers or new home sellers to deviate from the manufacturer's installation instructions. Consequently, the Commission proposes amending the Rule to clarify that the tolerance provision applies solely to claims made by manufacturers.

Comments Regarding How the Tolerance Limit Will Be Applied

NAIMA and Dow suggested clarifying the Rule to state more precisely how the tolerance limit would be applied. NAIMA suggested specifically requiring manufacturers to design their products to 100% of the claimed R-value, rather than aiming at the tolerance. NAIMA further recommended that the section require that the R-value of home insulation be no more than 5% below the listed R-value for the average of four randomly selected samples, and that the R-value of any single sample be no more than 10% below the listed R-value. NAIMA explained that limiting the tolerance to the average of four samples would make this section of the Rule consistent with current ASTM material standards. Dow asked that the Commission clarify the intent of section 460.8, and suggested the following language to allow some variability in a production lot (rather than simply permitting an R-value of up to 10% below the claimed value):

The mean R-Value of sampled specimens of a production lot must meet or exceed the R-Value shown in a label, fact sheet, ad or other promotional material. No individual specimen can have an R-Value more than 10% below the claimed R-Value.(82)

Discussion Regarding How the Tolerance Limit Will Be Applied

The tolerance limit provision was designed to give manufacturers the flexibility to use the most effective and least burdensome or costly quality control procedures necessary to maintain each product's R-value (and the density necessary to obtain the claimed R-value) within an acceptable limit. At this time, however, the Commission agrees that it would be appropriate to consider whether the Commission should include in the Rule additional, more specific, guidance about how manufacturers should apply the tolerance limit. Possible alternatives include the suggestions made by NAIMA and Dow. Consequently, the Commission solicits comments on whether and how it should propose amending the tolerance provision, and the benefits and burdens such an amendment would confer on consumers and insulation sellers.

Comments Regarding Sampling Procedures for the Tolerance Limit

NAIMA recommended amending section 460.8 to require manufacturers to select test specimens in accordance with ASTM C 390-79,(83) which is the sampling procedure required by all ASTM thermal insulation standards.(84)

Discussion Regarding Sampling Procedures for the Tolerance Limit

In the original rulemaking proceeding, the Commission concluded that the available sampling standards -- specifically ASTM C 390 and Military Standard 105(85) -- were not suitable for inclusion as requirements of the Rule because they were extremely complex and were not designed for sampling from a continual production process but, instead, were "lot" sampling procedures designed for use in individual transactions. Accordingly, the Commission left the choice of specific sampling methods to the manufacturer's discretion. Likewise, paragraph 3.1.6 of the current ASTM sampling specification, ASTM C 390-79 (1995), establishes sampling standards applicable to a specific "lot" or "batch" (which is defined as "a definite quantity of some product manufactured under conditions of production that are considered uniform"). Although the Rule does not require specific sampling procedures, it requires that manufacturers be able to prove that test samples they select are representative of ongoing production.

To address this issue, the Commission solicits comments on whether manufacturers currently use sampling procedures that do not result in the selection of test specimens that are representative of ongoing production; which specific procedures currently are available for use in sampling from continuing production (or how sampling procedures designed for specific lots could be used to select samples from continuing production); and whether the Commission should require the use of specific sampling procedures.

4. Use of Current Test Data

Comments

Dr. Yarbrough, for TN Tech, asserted that required R-value disclosures should be based on test data no more than two years old. He contended that normal quality control activities should require more frequent thermal tests than are currently performed, and that this would not unduly burden the industry. He also recommended that, because the properties of thermal insulation can change when the manufacturing process changes, thermal test data should be based on the current manufacturing process and equipment being used.(86) Dr. Yarbrough would exclude reflective insulations from this requirement because the thermal measurements for these products are much more expensive than tests for mass insulations. He recommended that a test on a reflective insulation be considered current if it conforms to ASTM C 1224 and the measurements were made on the product being marketed.(87)

Discussion

When the Commission promulgated the Rule, it considered, but rejected, a recommendation in the Staff Report that the Commission require manufacturers to repeat their R-value substantiation tests every 60 days, coupled with a 5% tolerance limit. The Commission explained that the rulemaking record pointed to no single retesting frequency that would be superior for all manufacturers, regardless of the type and amount of insulation they produce and sell and regardless of the variables that might affect the production of each type of insulation product. In addition, the record indicated that there was a limited availability of testing laboratories and testing equipment at that time to conduct the required testing for all manufacturers on a frequent basis.

Instead, the Commission determined to rely on a tolerance limit provision as the governing quality control mechanism.(88) It specified 10% as the acceptable tolerance limit, and required manufacturers to institute in-plant quality control procedures necessary to stay within that tolerance limit. This mechanism was designed to give manufacturers the flexibility to use whatever quality control procedures are necessary to ensure the accuracy of their R-value claims, using the most effective and efficient, but the least burdensome or costly, means possible within their technical expertise. If the manufacturer changed the raw materials used or the manufacturing process, however, the resulting insulation product would be a new home insulation product. The Rule requires manufacturers to conduct a new R-value test on each new home insulation product, and to disclose the R-value (and related information) of each new product based on the new test.

The Commission agrees that it is appropriate to consider whether current conditions would justify the Commission's requiring a more specific retesting quality control mechanism. In this regard, the Commission is interested in comments regarding how frequently manufacturers currently test their insulation products, how much the R-value of current production varies,(89) how frequently manufacturers change their products, whether they retest products that have changed, and what retesting schedule would be most appropriate to ensure the accuracy of R-value claims made to consumers. After considering the comments, the Commission will determine whether it should propose requiring a specific retesting schedule.

5. Determining the Thermal Performance of Reflective Insulations

Two basic forms of reflective insulation products are marketed for use in the residential market: (1) traditional single-sheet and multi-sheet reflective insulations; and (2) single-sheet radiant barrier reflective insulations. Traditional reflective insulation products normally are installed in closed cavities, such as walls. As explained in Part IV.D.2, above, the Rule requires that manufacturers of traditional reflective insulation products use specific test procedures to determine the R-values of their products, and that manufacturers and other sellers disclose R-values to consumers for specific applications.

Radiant barrier reflective insulations, on the other hand, are installed in attics facing the attic's open airspace. Although radiant barrier reflective insulations are covered by the R-value Rule, R-value claims are not appropriate for them because no generally accepted test procedure exists to determine the R-value of a radiant barrier reflective insulation installed in an open attic. Sellers who make energy savings claims for radiant barrier insulations, however, must have a reasonable basis for the claims under Section 460.19(a) of the Rule.

a. Traditional Reflective Insulations

i. Single-sheet Products

Comments

Three comments recommended allowing the use of updated or alternative test procedures to measure the emissivity of traditional single-sheet reflective insulations.(90) Celotex and PIMA(91) recommended requiring that emissivity be determined under ASTM E 408-71 (1990),(92) ASTM C 835-82 (1988),(93) or another method that provides comparable results. Dr. Wilkes, for ORNL, reported that ASTM is in the final stages of developing a procedure to measure the emittance of foil sheets with a portable Emissometer, and recommended that the Commission include this procedure in section 460.5(c) when ASTM adopts it.(94)

Discussion

ASTM now has adopted the procedure (ASTM C 1371-97)(95) that Dr. Wilkes recommended. Dr. Wilkes informed the Commission's staff that the procedure is a very simple, quick measurement, using an instrument that costs about $1,000. He also informed the staff that, while there is no meaningful statistical difference between the results of measurements under ASTM C 1371-97 and ASTM C 835-95, the ASTM C 835-95 procedure is considerably more complicated.

The Commission solicits comments on the accuracy, reliability, and consistency of each of these procedures in measuring emissivity; the costs of conducting the procedures; and whether the Commission should require that emissivity be measured by only one procedure to ensure that measurements of emissivity are accurate and reliable.

ii. Multi-sheet Products

Comments

The five comments that addressed the Rule's R-value testing requirements for traditional multi-sheet reflective foil insulations recommended requiring that R-values be determined according to the procedures specified in ASTM C 1224-93, either in addition to or instead of the two ASTM R-value test procedures specified in the Rule.(96) Dr. Wilkes, for ORNL, explained that ASTM C 1224-93 requires R-value testing according to ASTM C 236 or ASTM C 976, but specifies additional instrumentation for the tests and a method for calculating R-values based on the R-value test procedure measurements. He further recommended requiring that the tests be conducted at the mean test temperature and temperature differential specified in ASTM C 1224-93.(97)

Discussion

Traditional multi-sheet reflective insulations must be tested in an enclosed cavity system that includes air spaces. Testing such a system requires the construction of a test panel to contain the reflective insulation. R-values determined in these systems tests may vary depending on the size and configuration of the test panel, the materials used to construct the test panel, how mean temperature and temperature differential are measured, and the corrections for components such as framing members used in the test panel that are made in the calculation of R-values based on the test results. ASTM C 1224-93 includes requirements concerning the construction of the test panel, verification of the R-value measurement, and calculation of the R-value of the reflective insulation from the R-value measurement of the entire system. The Commission concludes that requiring standardization of these variables would be comparable to the Rule's requirements that test specimens of certain mass insulation products be prepared according to specified procedures and that R-values determined under ASTM C 177-85 (1993) or ASTM C 518-91 be reported in accordance with the requirements of ASTM C 1045-90, and would benefit consumers by making R-value claims for these products more accurate and reliable.

For these reasons, the Commission proposes requiring that R-values for reflective insulations be tested according to ASTM C 236-89 (1993) or ASTM C 976-90 in a test panel constructed according to ASTM C 1224-93, and under the test conditions specified in ASTM C 1224-93, and that the R-values be calculated according to the formula specified in ASTM C 1224-93 from the results of those R-value tests. The Commission solicits comments on this proposal.

b. Radiant Barrier Products

Comments

Dr. Wilkes, for ORNL, stated that ASTM is developing a method for evaluating the thermal performance of low-emittance foils used in residential attics to reduce radiative transport across the attic air space. He recommended that the Commission incorporate this method into the Rule once ASTM adopts it.(98)

Discussion

ASTM has now adopted the standard referred to by Dr. Wilkes. The standard, ASTM C 1340-96,(99) incorporates a complicated calculation (and computer program) to determine the heat flux through an attic containing a radiant barrier. The results do not determine an R-value rating, but instead a performance value that might serve as a reasonable basis for energy savings claims (and related performance claims) made about radiant barrier insulations. The Commission solicits comments concerning the specific type of performance the standard measures, how the standard may be used to substantiate energy savings claims or other performance claims for radiant barrier insulations, the types of installations of radiant barrier insulations for which the standard may be used, the accuracy of the determinations made under the standard, and whether the Commission should require that energy savings or other performance claims for radiant barrier insulations be based on the standard.

6. Additional Laboratory Procedures for Testing Loose-fill Insulations

Comments

NAIMA recommended that the Commission require testing of loose-fill insulations "in full conformance with ASTM C 687-93."(100) NAIMA explained that C 687 has been significantly improved since the Rule became effective and that it now deals more specifically with test specimen preparation techniques, stabilization times, and measurement of the specimen density in the test area, resulting in a significant improvement in test precision.(101)

Discussion

ASTM C 687-95 (the current ASTM specification) is a standard practice, rather than a test procedure. It specifies procedures to be followed in testing a variety of loose-fill insulations to be used in other than enclosed applications. It is a detailed laboratory procedures guide that appears to be both comprehensive and complicated. In an attempt to minimize burdens imposed by the Rule, the Commission limited its testing requirements to the minimums necessary to ensure the accuracy and reliability of test results. The Rule, therefore, specifies only the basic R-value test procedures and test specimen preparation procedures for certain products that are necessary to account for factors that can significantly affect R-value results (e.g., aging, settling). In the original rulemaking proceeding, the Commission considered, but rejected as unnecessary, requiring adherence to more detailed standard practice or standard guide specifications, such as ASTM C 687. Without data substantiating the need to specify detailed laboratory operating procedures, for these insulations or others, the Commission is reluctant to consider imposing additional requirements. The Commission invites public comments, however, on whether and why there is a need to specify in more detail the laboratory procedures that should be followed in preparing test specimens and conducting R-value test procedures, for loose-fill insulations as well as other forms of insulations, and the benefits and burdens from such additional requirements.

E. Other Disclosure Issues

1. Disclosures on Labels and Fact Sheets

a. "What You Should Know About R-values"

Comments

The Rule requires the manufacturer's fact sheet to include a specific statement entitled "What You Should Know About R-values" that explains the meaning of R-value and lists factors consumers should consider when purchasing insulation.(102) Regal suggested that this statement should be more specific in explaining how consumers can determine the amount of insulation they need. Regal commended the Insulation Fact Sheet published by the DOE for providing the best such information for consumers, but contended that it is not readily available in the marketplace. Regal also explained that the DOE ZIP Computer Program can be used to make a cost-benefit analysis for specific insulation products based on their cost per R-value and expected benefits.(103)

Corbond suggested that the current Rule has four negative effects that the Commission should address: (1) the Rule codifies the least effective measure of insulation performance, conductivity, as the sole measure widely used for comparing insulation value; (2) the Rule's emphasis on a product's R-value, as opposed to factors that affect installed performance, retards the development and acceptance of new products that perform better than fiberglass insulations because their performance appears the same when measured by R-value alone; (3) energy codes that require the installation of specific R-values favor products such as fiberglass insulations because the code requirements do not recognize the superior performance of insulations that are not subject to degradation of R-value in actual use due to factors such as venting, wind, convection, and moisture accumulation; and (4) the Rule perpetuates the use of an obsolete product, fiberglass insulation, which requires supplementation by other products and techniques (e.g., foam caulk, house-wrap, sheet vapor barriers, foam insulation sheathing, and venting) to help it do the job it should be able to do on its own.(104)

CIMA and Corbond recommended that the Commission add language to the required statement to address these concerns. CIMA recommended the following statement:(105)

R-value is important, but it is only one of many factors that affect the actual performance of insulation as installed. Other important factors to consider include air permeability, ability of the insulation to "tighten" the building against air infiltration, susceptibility to convective heat loss under cold conditions, and proper installation.

Corbond supported CIMA's suggestion, but recommended the use of an expanded version of the statement:

R-value is important, but it is only one of the many factors that affect the actual performance of insulation as installed. Other important factors to consider include air permeability, ability of the insulation to "tighten" the building against air infiltration, susceptibility to convective heat loss under cold conditions, the potential for moisture permeation and accumulation and its deteriorating effects, and proper installation. Consult your insulation manufacturer for information regarding the true performance efficiency of the insulation under conditions appropriate to your climate.

Discussion

The original purpose of the required explanation in fact sheets was to minimize disclosure burdens on industry members who advertise energy or fuel savings. Instead of requiring them to provide lengthy disclosures in ads that claim energy savings, the ad simply could refer consumers to information in the manufacturer's fact sheet.(106) This approach would ensure that the explanatory information would be made available to consumers, while keeping advertisements less cluttered.

The Commission recognizes that, as the comments have indicated, more information could be provided in the explanation about how consumers can purchase the most cost-effective amount of insulation, and that there are additional factors that can affect R-value and performance in actual use. The Commission drafted the statement to balance consumers' need for information against keeping the statement simple enough to be useful and not detract from its basic purpose -- making consumers aware that there are various factors they should consider when purchasing products to make their homes more energy efficient.

Because new information may be available about the factors that affect insulation performance, the Commission is willing to consider revising the explanation. The Commission is concerned, however, that many consumers would not understand the meaning or impact of a general cautionary statement that contains terms such as "air permeability," "susceptibility to convective heat loss under cold conditions," "the potential for moisture permeation and accumulation and its deteriorating effects." The Commission, therefore, solicits comments regarding how the explanation could be revised to provide the most useful information to assist consumers in making purchasing decisions. In particular, the Commission is interested in receiving information about the factors that should be included, why those factors are important, how the information could be explained in a meaningful and helpful manner, and how the information would assist consumers in making purchasing decisions. Among other things, commenters are requested to include data such as consumer perception studies that demonstrate whether suggested alternative disclosures would be meaningful to consumers.

b. Disclosures for Batt, Blanket, and Boardstock Insulations

Subsections 460.12(b)(1) and 460.12(b)(4) of the Rule require that manufacturers label all packages of batt/blanket insulations and boardstock insulations, respectively, with a chart showing the R-value, length, width, thickness, and square feet of insulation in the package, and 460.13(c)(1) requires that they include the chart on the manufacturer's fact sheets.

Comments Regarding Batt and Blanket Insulations

NAIMA recommended amending section 460.12(b)(1) to apply to all batt and blanket insulation products by deleting the reference to "mineral fiber." NAIMA asserted that batts and blankets made of other materials, such as cotton, other cellulosic materials, and plastic fiber, have been introduced into the marketplace and that the Rule should specify labeling requirements for these new batt and blanket products.(107)

Discussion Regarding Batt and Blanket Insulations

The Commission agrees that all types of batt and blanket insulations should be labeled with the same basic R-value and coverage area information, and that manufacturers' fact sheets for these insulation products should include these disclosures. Like other basic coverage chart disclosure requirements in section 460.12(b), the Commission designed this coverage chart disclosure requirement to apply to the form of the product (batt or blanket), not the type (e.g., mineral fiber). The Rule refers to "mineral fiber" batts and blankets because when the Rule was promulgated the batt and blanket insulation products being sold in the residential market were mineral fiber insulation products, primarily fiberglass. The Commission, therefore, proposes amending the Rule to clarify the requirement by deleting the phrase "mineral fiber" from section 460.12(b)(1),